Elimination of CO2 Cartridges for use in Restaurant Systems

GAFSED • April 24, 2023
A blue sign that says bulletin on it

DATE: April 24, 2023

TO: Authorized ANSUL® Restaurant System Distributors and OEMs

FROM:  Product Management, Restaurant Systems

SUBJECT:  Elimination of CO2 Cartridges for use in Restaurant Systems

 

As part of our improved delivery initiatives, we are continuing to review all components offered for sale.



To assist with production efficiency and reduced lead times we will be discontinuing the offering of CO2 cartridges for use in restaurant systems, effective May 1st, 2023. The impacted part numbers are listed below with the applicable Nitrogen Cartridge replacement.

CO2 cartridges existing in field installations and distributor inventory may still be used until they are no longer able to meet testing and certification requirements.


Elimination of CO2 Cartridges for use in Restaurant Systems

All existing and new orders placed by April 28th 2023 will be fulfilled as product becomes available.

Should you have questions pertaining to this bulletin please contact your Territory Sales Manager or Technical Services at the below listed number. 

Download Bulletin
ANSUL Bulletin 2026030: R-102 fryer and range protection under Jet Extract hoods
By GAFSED • October 29, 2026
ANSUL Bulletin 2026030 specifies R-102 single-nozzle protection for fryers and ranges under Jet Extract hoods, based on EN 17446 fire tests done by Johnson Controls.
ANSUL Bulletin 2026032: R-102 press-fit piping for restaurant fire suppression
By GAFSED • October 29, 2026
ANSUL Bulletin 2026032 approves press-fit distribution piping for the R-102 Restaurant Fire Suppression System to EN 17446. Review the tube and fitting requirements.
Arnold Edward Harner memorial Georgia fire safety industry ordained minister
By GAFSED • June 7, 2026
Arnold Harner June 3 2026 age 67 Rome Georgia. Past president Georgia Fire Safety Equipment Association. Ordained minister. Celebration of Life Service June 8 2026.
Final notice for servicing ANSUL K-GUARD extinguishers made between 2013–2020 per safety bulletin.
By GAFSED • November 3, 2025
ANSUL K-GUARD Class-K fire extinguishers manufactured from 2013–2020 may fail to discharge. Service affected units by Dec. 31, 2025.
DoD reinstates fire extinguisher requirements on military bases per NFPA 1 and NFPA 101 updates.
By GAFSED • September 26, 2025
Congress now requires the DoD to reinstall portable fire extinguishers on military bases in line with NFPA codes, reversing prior removal policies.
NAFED
By GAFSED • March 6, 2025
NAFED mourns the passing of fire safety industry leader Mike Laderoute, who dedicated five decades to fire protection. A Lifetime Achievement Award recipient, he was a mentor, educator, and innovator. Share memories and read his full obituary here.
NOTICE OF ENFORCEMENT DISCRETION REGARDING CYLINDERS THAT HAVE EXCEEDED THEIR PERIODIC REQUALIFICATI
By GAFSED • October 11, 2024
The U.S. Department of Transportation’s Pipeline and Hazardous Materials Safety Administration (PHMSA) understands that due to the flooding and damage caused by Hurricane Helene, many members of the medical and industrial gas industry may be experiencing difficulty in obtaining cylinders due to the increased demand for these gases or a disruption in the normal business model for cylinder exchange and testing facilities.
A fire extinguisher is attached to a map of georgia.
By GAFSED • October 11, 2024
Portable fire extinguishers and fire extinguisher system components may be serviced by companies not located in this state, when a company licensed by the Safety Fire Division has placed their own tag upon that extinguisher.
lithium-ion batteries
By GAFSED • October 3, 2024
As the prevalence of lithium-ion batteries in our daily environment continues to increase, so does the need for a fire protection solution. To capitalize on this growing market, several companies have introduced fire extinguishers to the marketplace that claim to address the multiple hazards associated with lithium-ion thermal runaway/fire events.
NFPA 96 2017 Edition
By GAFSED • March 26, 2024
NFPA 96 2017 Edition, the currently adopted edition which does not change in the latest edition published by NFPA, requires that at minimum there be an audible OR visible indicator to show that the system has activated. In 10.6.2 it requires that IF the building has a fire alarm system the activation of the extinguishing system shall activate the building fire alarm system.